Posted: Fri Jun 24, 2022 1:43 pm Post subject: Temperature Setting on Seaward Hot Water Heater |
|
|
Hello, I have a Seaward hot water heater, model S700 on my 2007 25' c-dory. The water coming out of that thing is dangerously hot. I can't figure out a way to turn down the max temp on the heater. Perhaps there is not a way. The manual says nothing about this and I can't find much online either. Does anybody else have any experience with these? Thanks. |
|
Back to top |
|
 |
smckean (Tosca)
Joined: 18 Jan 2014 Posts: 955 City/Region: Guemes Island (Anacortes)
State or Province: WA
C-Dory Year: 2005
C-Dory Model: 25 Cruiser
Vessel Name: Tosca
Photos: Tosca
|
Posted: Fri Jun 24, 2022 5:33 pm Post subject: |
|
|
I have the same model on my 2005 CD25. There are 2 "thingies" on the front of the unit with wires going to them. One is pretty obviously the heating element (part #73129); the other is the "hi-limit" thermostat part (#74563). It is the thermostat that tells the heater when the water is hot enough to stop heating. If this thermostat is fine, there is no way to change the "set point" temperature -- the temperature is the temperature; but if it's bad, the heater may just keep on heating.
I replace both these parts 2 years ago. I wanted a 1000 watt element (less load on generator), and I replaced the thermostat too for good measure (the part was relatively cheap as I remember). Note you do not have to drain the tank to replace the thermostat; it does not penetrate the tank.
P.S. You might be able to buy a different but compatible thermostat with a lower set point. _________________ Sandy McKean
Purchased Tosca in 2014
Re-powered to Yammi 200 in 2015 |
|
Back to top |
|
 |
johnr
Joined: 08 Apr 2007 Posts: 307 City/Region: Bellingham
State or Province: WA
C-Dory Year: 2007
C-Dory Model: 25 Cruiser
Vessel Name: Stillwater
Photos: Surf Scoter
|
Posted: Sat Jun 25, 2022 12:14 am Post subject: |
|
|
smckean (Tosca) wrote: | I have the same model on my 2005 CD25. There are 2 "thingies" on the front of the unit with wires going to them. One is pretty obviously the heating element (part #73129); the other is the "hi-limit" thermostat part (#74563). It is the thermostat that tells the heater when the water is hot enough to stop heating. If this thermostat is fine, there is no way to change the "set point" temperature -- the temperature is the temperature; but if it's bad, the heater may just keep on heating.
I replace both these parts 2 years ago. I wanted a 1000 watt element (less load on generator), and I replaced the thermostat too for good measure (the part was relatively cheap as I remember). Note you do not have to drain the tank to replace the thermostat; it does not penetrate the tank.
P.S. You might be able to buy a different but compatible thermostat with a lower set point. |
Thanks Sandy, good info. I'll check that out. |
|