View previous topic :: View next topic |
Author |
Message |
Hunkydory
Joined: 28 Mar 2005 Posts: 2660 City/Region: Cokeville, Wyoming
State or Province: WY
C-Dory Year: 2000
C-Dory Model: 22 Cruiser
Vessel Name: Hunkydory
Photos: Hunkydory-Jay-and-Jolee
|
Posted: Sun Nov 02, 2008 1:17 pm Post subject: Shore power possible short |
|
|
Hope someone has an obvious answer to this that I'm missing.
Yesterday while I was changing the moter lower unit fluid I at times noticed an unpleasant tingling burning sensation when just brushing the moter with my hands. The boat is put up for the winter on the trailer and the trailer on blocks. The shore power was plugged in to top off the battery. The tingling would stop when the shore power plug was turned off. Our home is the old style only two wire one being ground system. Could this be the cause and I just need to ground the boat or is a short somewhere the likely problem.
Jay _________________ Jay and Jolee 2000 22 CD cruiser Hunkydory
I will not waste my days in trying to prolong them------Jack London
https://share.delorme.com/JuliusByers |
|
Back to top |
|
|
Captains Cat
Joined: 03 Nov 2003 Posts: 7313 City/Region: Cod Creek>Potomac River>Chesapeake Bay
State or Province: VA
C-Dory Year: 2005
C-Dory Model: 22 Cruiser
Vessel Name: Captain's Choice II
Photos: Captain's Cat
|
Posted: Sun Nov 02, 2008 2:39 pm Post subject: |
|
|
I guess with a two wire system, you cannot use a GFI breaker on the pier for your shore power?
charlie _________________ CHARLIE and PENNY CBRAT #100
Captain's Cat II 2005 22 Cruiser
Thataway (2006 TC255 - Sold Aug 2013)
Captain's Cat (2006 TC255 - Sold January 2012)
Captain's Kitten (1995 CD 16 Angler- Sold June 2010)
Captain's Choice (1994 CD 22 Cruiser- Sold Jun 2007)
Potomac River/Chesapeake Bay
K4KBA |
|
Back to top |
|
|
Hunkydory
Joined: 28 Mar 2005 Posts: 2660 City/Region: Cokeville, Wyoming
State or Province: WY
C-Dory Year: 2000
C-Dory Model: 22 Cruiser
Vessel Name: Hunkydory
Photos: Hunkydory-Jay-and-Jolee
|
Posted: Sun Nov 02, 2008 2:52 pm Post subject: |
|
|
Charlie
The boat shore power is 3 wire, so no problem when at a slip and connecting into shore power with the boat in the water or at least there wasn't this summer when I was hooked up a lot at the Bridge Bay Marina slip on Yellowstone Lake. Its the old home and its two wire system that I think may be causing the problem on the boat. I just don't know enough about it to be sure. Know one thing and that's the tingle could turn into a bad bite, so here I am looking for help.
Jay |
|
Back to top |
|
|
Sea Wolf
Joined: 01 Nov 2003 Posts: 8650 City/Region: Redding
State or Province: CA
C-Dory Year: 1987
C-Dory Model: 22 Cruiser
Vessel Name: Sea Wolf
Photos: Sea Wolf
|
Posted: Sun Nov 02, 2008 3:00 pm Post subject: |
|
|
Jay-
Some questions:
Do you experience this same type of problem inside the house or when using any other outdoor tools on extension cords?
Does the outlet from the house have one plug in connector longer (wider) than the other?
Does your extension cord have one connector longer (wider) than the other?
Are you using a three prong adaptor on the extension cord that has a green wire ground that is designed to be screwed into the outlet center screw for a ground? Is it connected?
Can your shore power cord adaptor from the boat be plugged into the extension cord either of two ways, reversing the polarity in effect?
Does your shore power system have a GFI Ground Field Interrupter circuit in it? Has it tripped at all?
Is the battery charger hard wired to the 12 volt circuit or plugged into a wall socket? Can the leads be inverted on the 120 volt side?
If you place a digital voltmeter between the motor and a grounded rod into the soil, how many AC volts does it read? BE CAREFUL HERE, THE VOLTAGE BETWEEN THE MOTOR AND THE GROUND MAY SEEM A LOT MORE WHEN USING A FULLY GROUNDED ROD!
Is there any chance that any of the return ("grounded") side of the circuit is poorly connected , giving a weak ground/return path?
Place the digital voltmeter between the grounded side and the rod out at the boat and see if there's any apparent voltage.?????
Thanks all for now, gotta go, be back later!
Joe. _________________ Sea Wolf, C-Brat #31
Lake Shasta, California
"Most of my money I spent on boats and women. The rest I squandered'. " -Annonymous |
|
Back to top |
|
|
journey on
Joined: 03 Mar 2005 Posts: 3597 City/Region: Valley Centre
State or Province: CA
C-Dory Year: 2005
C-Dory Model: 25 Cruiser
Vessel Name: journey on
Photos: Journey On
|
Posted: Sun Nov 02, 2008 3:02 pm Post subject: |
|
|
You know, I have the same problem with Journey On when it's at home and on the trailer. I use only a 2 wire system to the boat, power and return, no earth (green) wire The motor's a Honda, and I don't know how 110 VAC gets to the motor. However, I've got a shock or two that catches one's attention.
What I'm going to try is to use a local earth, since the green wire goes directly to ground (as does the white wire, eventually.) My only reluctance is how it'll affect the GFI in the garage.
I'd still love to hear how the motor gets 110 VAC on it. Then I'd be happy. The only place where the 12 VDC and 110 VAC come into contact is the inverter and battery charger. The inverter is off by a switch, and I don't know about the Xantrex charger.
Boris |
|
Back to top |
|
|
Hunkydory
Joined: 28 Mar 2005 Posts: 2660 City/Region: Cokeville, Wyoming
State or Province: WY
C-Dory Year: 2000
C-Dory Model: 22 Cruiser
Vessel Name: Hunkydory
Photos: Hunkydory-Jay-and-Jolee
|
Posted: Sun Nov 02, 2008 3:28 pm Post subject: |
|
|
Joe
No problems ever in the home or when using other tools in the past. Though have been told that's the problem with the old two wire system without the third direct ground wire it doesn't have the built in safety net.
The outlet from house that I'm using to connect to the boat is actually a two prong outlet in my shed run from a breaker in the house. Yes it does have the one outlet wider than the other and if I understand it correctly that is for polarity.
My extension cord is a 30 amp Marine cord from West Marine that I must use a two prong adapter to connect to shed outlet.
No there is no connection with green wire. Just Marine cord adapted to plug into the two prong.
No I cannot reverse the polarity at the boat, but would be simple to do at the outlet. Would even be simpler if I had a polarity checker.
Don't know if I have ground field interrupter in the shore power circuit, but do know breaker hasn't tripped and if I turn the breaker off and leave power connected to the incoming connector to the boat it doesn't tingle at the moter.
The battery charger is built into the shore power system with its own breaker and automatically charges the batteries if needed and at the time I was servicing the moters it was needed.
My youngest son has my volt meter at his place, so may take a bit to make voltage test between ground and boat, but i will.
Could be a chance of the return being poorly connected. Will have to check.
And the thanks is all to you,
Jay |
|
Back to top |
|
|
marvin4239
Joined: 06 Feb 2007 Posts: 1165 City/Region: Jacksonville Florida/Wilmington NC
State or Province: FL
C-Dory Year: 2007
C-Dory Model: 22 Cruiser
Vessel Name: C-FLE II
Photos: C-FLE II
|
Posted: Sun Nov 02, 2008 3:30 pm Post subject: |
|
|
I've experienced the same problem when my boat is on the trailer and plugged into a circuit in a shed 100' from my main panel. I found that if I turn off the breaker to the battery charger the problem disappears. I don't (thank God) experience the same problem when my boat is suspended in the lift and plugged in with me standing in waste deep water beside it. My dock power is well grounded so I can only assume the stray voltage is being directed to the ground through the grounding circuit rather than through me! I don't have ground fault protection circuits at either location. The ground resistance at the shed location is pretty high so I suppose I make a better ground as when I notice this the ground is usually wet from me washing the boat. Why I have this stray voltage is a mystery to me as I also have a galvonic protection device. I have a portable GFI that I plan to use in the future. What I experience is more of a tingle rather than and AC type shock. _________________ marvin |
|
Back to top |
|
|
Hunkydory
Joined: 28 Mar 2005 Posts: 2660 City/Region: Cokeville, Wyoming
State or Province: WY
C-Dory Year: 2000
C-Dory Model: 22 Cruiser
Vessel Name: Hunkydory
Photos: Hunkydory-Jay-and-Jolee
|
Posted: Sun Nov 02, 2008 3:35 pm Post subject: |
|
|
Well, Boris and Marvin, If may not be good to you, but I'm happy to know there are at least three of us in the same boat so to speak still surviving. Yes now and again it does get your full attention. I'm glad yours stays only a tingle Marvin.
Jay |
|
Back to top |
|
|
marvin4239
Joined: 06 Feb 2007 Posts: 1165 City/Region: Jacksonville Florida/Wilmington NC
State or Province: FL
C-Dory Year: 2007
C-Dory Model: 22 Cruiser
Vessel Name: C-FLE II
Photos: C-FLE II
|
Posted: Sun Nov 02, 2008 4:05 pm Post subject: |
|
|
I don't think GFI's will do you any good if you are using a two wire cord from it to your boat. In my case I think I simply don't have a good ground in my shed. Either way something isn't correct and I suspect the battery charger. Mine is a factory installed Guest. My plan is to drive and earthen ground close to where I store my boat on land and measure the voltage between the motor and the earthen ground and perhaps find if it's AC or DC potential and how much. This is a little embarrasing to admit but I spent 40 years working as and electrician so my tolerance may be a little higher than most, I've been shocked a lot! |
|
Back to top |
|
|
Hunkydory
Joined: 28 Mar 2005 Posts: 2660 City/Region: Cokeville, Wyoming
State or Province: WY
C-Dory Year: 2000
C-Dory Model: 22 Cruiser
Vessel Name: Hunkydory
Photos: Hunkydory-Jay-and-Jolee
|
Posted: Sun Nov 02, 2008 4:17 pm Post subject: |
|
|
Yikes!!!!! Just measured from motor to ground and its a full 110 VAC. Through all those tingles and burns I'd been standing and kneeling in water saturated ground from running the motors before working on them. My nerves must not be conducting at my present age like in the past. My charger is a Guest mounted at the factory like Marvin's and when I tripped the charge breaker no voltage then from the motors to ground. Marvin at least with your experience you're making me feel a little bettor for not being able to solve this on my own
Jay |
|
Back to top |
|
|
thataway
Joined: 02 Nov 2003 Posts: 20829 City/Region: Pensacola
State or Province: FL
C-Dory Year: 2007
C-Dory Model: 25 Cruiser
Vessel Name: thataway
Photos: Thataway
|
Posted: Sun Nov 02, 2008 4:35 pm Post subject: |
|
|
There is a good chance, that the black and white wire are reversed at the plug, or somewhere in the circuit. I have found that with long runs to my lifts in the past, that there was some voltage leakage--and that ground potential was not the same at the boat lift, as at the meter box (where the circuit--neutral and ground--are tied to ground. My "cure" was both to put in new wire, in dry conduit (probably not your problem), and put a second ground rod at the lift. The green wire was tied to this rod. You could put in a ground rod near the extension cord and ground that.
My worry would be the possibility of electrolysis of the motor, if it were submerged with these conditions. (as well as potential injury to the boat owner).
I don't know if these C Dories have the galvanic isolators, or not. My 25 does not have it, the Tom Cat does. ABYC I believe requires the galvanic isolator.
There is also the possablity that you are getting pulsed DC at 14 volts thru the battery charger--to the ground of the battery (and the motor). Because the battery charger does not have its green wire (ground) attatched, the pulse is now going through your body to ground. The question is how good is the ground isolation (shoes worn?--as Joe suggests--if you have the ground rod and then hold it, and touch the engine, there may be a lot more current flowing, where you are isolated to a reasonable extent with shoes on--but if you are kneeling on wet ground--that will have a more conductive effect than standing.
Check the voltage first--see how much AC and DC voltage there is from the engine to ground. Take the ground point at the battery, since that will be connected to the engine, and you can clamp a lead on there. Consider putting a 3 wire circuit to the boat--a ground rod near the outlet in the shop/garage, and perhaps looking into a galvanic isolation circuit--especially if the boat is left in the water. _________________ Bob Austin
Thataway
Thataway (Ex Seaweed) 2007 25 C Dory May 2018 to Oct. 2021
Thisaway 2006 22' CDory November 2011 to May 2018
Caracal 18 140 Suzuki 2007 to present
Thataway TomCat 255 150 Suzukis June 2006 thru August 2011
C Pelican; 1992, 22 Cruiser, 2002 thru 2006
Frequent Sea; 2003 C D 25, 2007 thru 2009
KA6PKB
Home port: Pensacola FL |
|
Back to top |
|
|
marvin4239
Joined: 06 Feb 2007 Posts: 1165 City/Region: Jacksonville Florida/Wilmington NC
State or Province: FL
C-Dory Year: 2007
C-Dory Model: 22 Cruiser
Vessel Name: C-FLE II
Photos: C-FLE II
|
Posted: Sun Nov 02, 2008 4:49 pm Post subject: |
|
|
Hunkydory wrote: | Yikes!!!!! Just measured from motor to ground and its a full 110 VAC. Through all those tingles and burns I'd been standing and kneeling in water saturated ground from running the motors before working on them. My nerves must not be conducting at my present age like in the past. My charger is a Guest mounted at the factory like Marvin's and when I tripped the charge breaker no voltage then from the motors to ground. Marvin at least with your experience you're making me feel a little bettor for not being able to solve this on my own
Jay |
Wow now thats scary. No idea what my voltage is boats presently in the lift. Like Bob my boat lift is 1,000 from the service ground and I added a second ground for the lift at the dock. On a long run like that the ground wire resistance could easily be higher than your body resistance standing in water. What I felt was more like low voltage pulsating DC I was barefoot standing in wash water. I'll be checking mine tommorrow. My boat has the factory installed galvonic isolater I'd assume if it's properly wired it would eliminate the problem? |
|
Back to top |
|
|
thataway
Joined: 02 Nov 2003 Posts: 20829 City/Region: Pensacola
State or Province: FL
C-Dory Year: 2007
C-Dory Model: 25 Cruiser
Vessel Name: thataway
Photos: Thataway
|
Posted: Sun Nov 02, 2008 5:25 pm Post subject: |
|
|
We must have double posted...if it is 110 volts, then the neutral and ground are reversed somewhere in the circuit--most likely at the plug in the garage, but it could be in the boat (stranger things have happened). There a direct connection between the neutral (white wire) and gound somewhere on the boat. You need to trace this out--I would check the plug first...and work from there, plus put in a ground to the boat circuit. |
|
Back to top |
|
|
MikeMac
Joined: 11 Apr 2005 Posts: 83 City/Region: Stafford
State or Province: TX
C-Dory Year: 1984
C-Dory Model: 22 Classic
Photos: MikeMac
|
Posted: Sun Nov 02, 2008 5:46 pm Post subject: Stray currents |
|
|
Hi folks,
This thread highlights one of my concerns about boats, electricity, and stray currents in marinas. A few days ago somebody asked about leaving their boat plugged in to shore power for five months. I was going to post a reply, but thought why start a ruckus. When you plug into a shore power system your boat can become part of the whole circuit with all the other boats through the power system and the water. Some of those boats are likely wired by amateurs or even professionals who shouldn't even do house wiring, let alone marine systems. If one is close by, your boat, or you, can wind up being the ground path for somebody's crummy wiring job. I don't even like to be in the water in marinas because of the potential for stray currents. Be careful, there are lots of hot marinas wth bad galvanic corrosion problems.
Best of luck,
Mike |
|
Back to top |
|
|
Hunkydory
Joined: 28 Mar 2005 Posts: 2660 City/Region: Cokeville, Wyoming
State or Province: WY
C-Dory Year: 2000
C-Dory Model: 22 Cruiser
Vessel Name: Hunkydory
Photos: Hunkydory-Jay-and-Jolee
|
Posted: Sun Nov 02, 2008 8:19 pm Post subject: |
|
|
Tried rechecking voltage at motors to ground with power coming from a different source then the house. No voltage from motors to ground, then hooked back up to house and wouldn't you know no voltage from motors to ground now there either. The only difference being the batteries are now charged. Could this wayward current be coming only from the charger to motors while it is actually in the process of charging batteries. Also noticed the shore power breaker box has an incoming correct polarity check and its ok.
Jay |
|
Back to top |
|
|
|